Pooja Group

CPK

CPK

CPK pumps are horizontal, radially split, single-stage, single-entry volute casing process pumps in back pull-out design, with radial impeller, to EN 22858 / ISO 2858 / ISO 5199. Complemented by pumps of DN 250.

CPK pumps are horizontal, radially split, single-stage, single-entry volute casing process pumps in back pull-out design, with radial impeller, to EN 22858 / ISO 2858 / ISO 5199. Complemented by pumps of DN 250.

Key Technical Information

Max. flow rate

1100 m3/h

Max. head

90 m

Max. allowed working pressure

25 bar

Maximum allowable fluid temperature

200 °C

Max. flow rate

60 m3/h

Max. head

38 m

Maximum allowable fluid temperature

33 °C

Applications

1.

Function

Pump

2.

Drive concept

With electric actuator

3.

Max. flow rate

60 m3/h

4.

Min. flow rate

4 m3/h

5.

Max. head

38 m

6.

Min. head

6 m

7.

Mains frequency

50 Hz

8.

Drive concept

With electric actuator

9.

Mains voltage

220 V,
240 V,
380 V,
415 V

10.

Suction behaviour

Non-self-priming

11.

Maximum allowable fluid temperature

33 °C

1. Function Pump
2. Connection type Flange
3. Drive concept With electric actuator
4. Max. flow rate 1100 m3/h
5. Min. flow rate 250 m3/h
6. Max. head 90 m
7. Min. head - 19 m
8. Mains frequency 50 Hz,60 Hz
9. Mains voltage 415 V
10. Casing material IS 210 GR FG260, A216 GR WCB, A995 GR 1B, A743 GR CF8, A743 GR CF8M
11. Nominal pressure PN 25
12. Max. allowed working pressure 25 bar
13. Suction behaviour Non-self-priming
14. Maximum allowable fluid temperature 200 °C
15. Minimum allowable fluid temperature -70 °C