Pooja Group

Etanorm

Etanorm

Horizontal volute casing pump, single-stage, with ratings and main dimensions to EN 733, long-coupled, back pull-out design, with replaceable shaft sleeves / shaft protecting sleeves and casing wear rings, with motor-mounted variable speed system. With KSB SuPremE, a magnetless synchronous reluctance motor (exception: motor sizes 0.55 kW / 0.75 kW with 1500 rpm are designed with permanent magnets) of efficiency class IE4/IE5 to IEC TS 60034-30-2:2016, for operation on a KSB PumpDrive 2 or KSB PumpDrive 2 Eco variable speed system without rotor position sensors. Motor mounting points in accordance with EN 50347, envelope dimensions in accordance with DIN V 42673 (07-2011). ATEX-compliant version available.

Horizontal volute casing pump, single-stage, with ratings and main dimensions to EN 733, long-coupled, back pull-out design, with replaceable shaft sleeves / shaft protecting sleeves and casing wear rings, with motor-mounted variable speed system. With KSB SuPremE, a magnetless synchronous reluctance motor (exception: motor sizes 0.55 kW / 0.75 kW with 1500 rpm are designed with permanent magnets) of efficiency class IE4/IE5 to IEC TS 60034-30-2:2016, for operation on a KSB PumpDrive 2 or KSB PumpDrive 2 Eco variable speed system without rotor position sensors. Motor mounting points in accordance with EN 50347, envelope dimensions in accordance with DIN V 42673 (07-2011). ATEX-compliant version available.

Key Technical Information

Max. flow rate

1368 m3/h

Max. head

160 m

Max. allowed working pressure

16 bar

Maximum allowable fluid temperature

140 °C

Max. flow rate

60 m3/h

Max. head

38 m

Maximum allowable fluid temperature

33 °C

Applications

1.

Function

Pump

2.

Drive concept

With electric actuator

3.

Max. flow rate

60 m3/h

4.

Min. flow rate

4 m3/h

5.

Max. head

38 m

6.

Min. head

6 m

7.

Mains frequency

50 Hz

8.

Drive concept

With electric actuator

9.

Mains voltage

220 V,
240 V,
380 V,
415 V

10.

Suction behaviour

Non-self-priming

11.

Maximum allowable fluid temperature

33 °C

1. Function Pump
2. Connection type Flange
3. Drive concept With electric actuator, Combustion engine
4. Max. flow rate 1368 m3/h
5. Min. flow rate 1.5 m3/h
6. Max. head 160 m
7. Min. head 2 m
8. Mains frequency 50 Hz, 60 Hz
9. Mains voltage 400 V, 460 V, 220 V, 230 V, 240 V, 380 V, 415 V, 500 V, 575 V, 660 V, 690 V
10. Casing material EN-GJL-250/A48 CL 35B, CC480K-GS/B30 C90700, 1.4408/A743CF8M, EN-GJS-400-15/A536 GR 60-40-18
11. Nominal pressure PN 16, PN 10, CL 150, CL 125
12. Max. allowed working pressure 16 bar
13. Suction behaviour Non-self-priming
14. Maximum allowable fluid temperature 140 °C
15. Minimum allowable fluid temperature -30 °C