Vertical turbine pump conforming to AWWA E101-88 and designed with radially split interchangeable pump bowls, wear rings and impellers; column assembly with interchangeable column bearings and lengths of column pipes for variable immersion depths.
2600 m3/h
160 m
16 bar
105 °C
60 m3/h
38 m
33 °C
| 1. | Function | Pump |
| 2. | Connection type | Flat version |
| 3. | Drive concept | With electric actuator |
| 4. | Max. flow rate | 2600 m3/h |
| 5. | Min. flow rate | 13 m3/h |
| 6. | Max. head | 160 m |
| 7. | Mains frequency | 50 Hz, 60 Hz |
| 8. | Mains voltage | 230 V, 400 V, 460 V |
| 9. | Casing material | EN-GJL-250, EN-GJSA-XNICR20-2, NORINOX 1.4408, 1.4517, 1.4469, CC480K-GS |
| 10. | Nominal pressure | PN 16 |
| 11. | Max. allowed working pressure | 16 bar |
| 12. | Suction behaviour | Non-self-priming |
| 13. | Maximum allowable fluid temperature | 105 °C |
| 14. | Minimum allowable fluid temperature | 0 °C |